| * Samsung S2MPS11 and S2MPS14 Voltage and Current Regulator |
| |
| The Samsung S2MPS11 is a multi-function device which includes voltage and |
| current regulators, RTC, charger controller and other sub-blocks. It is |
| interfaced to the host controller using an I2C interface. Each sub-block is |
| addressed by the host system using different I2C slave addresses. |
| |
| Required properties: |
| - compatible: Should be "samsung,s2mps11-pmic" or "samsung,s2mps14-pmic". |
| - reg: Specifies the I2C slave address of the pmic block. It should be 0x66. |
| |
| Optional properties: |
| - interrupt-parent: Specifies the phandle of the interrupt controller to which |
| the interrupts from s2mps11 are delivered to. |
| - interrupts: Interrupt specifiers for interrupt sources. |
| |
| Optional nodes: |
| - clocks: s2mps11 provides three(AP/CP/BT) buffered 32.768 KHz outputs, so to |
| register these as clocks with common clock framework instantiate a sub-node |
| named "clocks". It uses the common clock binding documented in : |
| [Documentation/devicetree/bindings/clock/clock-bindings.txt] |
| - #clock-cells: should be 1. |
| |
| - The following is the list of clocks generated by the controller. Each clock |
| is assigned an identifier and client nodes use this identifier to specify |
| the clock which they consume. |
| Clock ID |
| ---------------------- |
| 32KhzAP 0 |
| 32KhzCP 1 |
| 32KhzBT 2 |
| |
| - regulators: The regulators of s2mps11 that have to be instantiated should be |
| included in a sub-node named 'regulators'. Regulator nodes included in this |
| sub-node should be of the format as listed below. |
| |
| regulator_name { |
| [standard regulator constraints....]; |
| }; |
| |
| regulator-ramp-delay for BUCKs = [6250/12500/25000(default)/50000] uV/us |
| |
| BUCK[2/3/4/6] supports disabling ramp delay on hardware, so explictly |
| regulator-ramp-delay = <0> can be used for them to disable ramp delay. |
| In the absence of the regulator-ramp-delay property, the default ramp |
| delay will be used. |
| |
| NOTE: Some BUCKs share the ramp rate setting i.e. same ramp value will be set |
| for a particular group of BUCKs. So provide same regulator-ramp-delay<value>. |
| Grouping of BUCKs sharing ramp rate setting is as follow : BUCK[1, 6], |
| BUCK[3, 4], and BUCK[7, 8, 10] |
| |
| The regulator constraints inside the regulator nodes use the standard regulator |
| bindings which are documented elsewhere. |
| |
| The following are the names of the regulators that the s2mps11 pmic block |
| supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number |
| as per the datasheet of s2mps11. |
| |
| - LDOn |
| - valid values for n are: |
| - S2MPS11: 1 to 38 |
| - S2MPS14: 1 to 25 |
| - Example: LDO1, LD02, LDO28 |
| - BUCKn |
| - valid values for n are: |
| - S2MPS11: 1 to 10 |
| - S2MPS14: 1 to 5 |
| - Example: BUCK1, BUCK2, BUCK9 |
| |
| Example: |
| |
| s2mps11_pmic@66 { |
| compatible = "samsung,s2mps11-pmic"; |
| reg = <0x66>; |
| |
| s2m_osc: clocks{ |
| #clock-cells = 1; |
| clock-output-names = "xx", "yy", "zz"; |
| }; |
| |
| regulators { |
| ldo1_reg: LDO1 { |
| regulator-name = "VDD_ABB_3.3V"; |
| regulator-min-microvolt = <3300000>; |
| regulator-max-microvolt = <3300000>; |
| }; |
| |
| ldo2_reg: LDO2 { |
| regulator-name = "VDD_ALIVE_1.1V"; |
| regulator-min-microvolt = <1100000>; |
| regulator-max-microvolt = <1100000>; |
| regulator-always-on; |
| }; |
| |
| buck1_reg: BUCK1 { |
| regulator-name = "vdd_mif"; |
| regulator-min-microvolt = <950000>; |
| regulator-max-microvolt = <1350000>; |
| regulator-always-on; |
| regulator-boot-on; |
| }; |
| |
| buck2_reg: BUCK2 { |
| regulator-name = "vdd_arm"; |
| regulator-min-microvolt = <950000>; |
| regulator-max-microvolt = <1350000>; |
| regulator-always-on; |
| regulator-boot-on; |
| regulator-ramp-delay = <50000>; |
| }; |
| }; |
| }; |