| uGuru datasheet |
| =============== |
| |
| First of all, what I know about uGuru is no fact based on any help, hints or |
| datasheet from Abit. The data I have got on uGuru have I assembled through |
| my weak knowledge in "backwards engineering". |
| And just for the record, you may have noticed uGuru isn't a chip developed by |
| Abit, as they claim it to be. It's realy just an microprocessor (uC) created by |
| Winbond (W83L950D). And no, reading the manual for this specific uC or |
| mailing Windbond for help won't give any usefull data about uGuru, as it is |
| the program inside the uC that is responding to calls. |
| |
| Olle Sandberg <ollebull@gmail.com>, 2005-05-25 |
| |
| |
| Original version by Olle Sandberg who did the heavy lifting of the initial |
| reverse engineering. This version has been almost fully rewritten for clarity |
| and extended with write support and info on more databanks, the write support |
| is once again reverse engineered by Olle the additional databanks have been |
| reverse engineered by me. I would like to express my thanks to Olle, this |
| document and the Linux driver could not have been written without his efforts. |
| |
| Note: because of the lack of specs only the sensors part of the uGuru is |
| described here and not the CPU / RAM / etc voltage & frequency control. |
| |
| Hans de Goede <j.w.r.degoede@hhs.nl>, 28-01-2006 |
| |
| |
| Detection |
| ========= |
| |
| As far as known the uGuru is always placed at and using the (ISA) I/O-ports |
| 0xE0 and 0xE4, so we don't have to scan any port-range, just check what the two |
| ports are holding for detection. We will refer to 0xE0 as CMD (command-port) |
| and 0xE4 as DATA because Abit refers to them with these names. |
| |
| If DATA holds 0x00 or 0x08 and CMD holds 0x00 or 0xAC an uGuru could be |
| present. We have to check for two different values at data-port, because |
| after a reboot uGuru will hold 0x00 here, but if the driver is removed and |
| later on attached again data-port will hold 0x08, more about this later. |
| |
| After wider testing of the Linux kernel driver some variants of the uGuru have |
| turned up which will hold 0x00 instead of 0xAC at the CMD port, thus we also |
| have to test CMD for two different values. On these uGuru's DATA will initally |
| hold 0x09 and will only hold 0x08 after reading CMD first, so CMD must be read |
| first! |
| |
| To be really sure an uGuru is present a test read of one or more register |
| sets should be done. |
| |
| |
| Reading / Writing |
| ================= |
| |
| Addressing |
| ---------- |
| |
| The uGuru has a number of different addressing levels. The first addressing |
| level we will call banks. A bank holds data for one or more sensors. The data |
| in a bank for a sensor is one or more bytes large. |
| |
| The number of bytes is fixed for a given bank, you should always read or write |
| that many bytes, reading / writing more will fail, the results when writing |
| less then the number of bytes for a given bank are undetermined. |
| |
| See below for all known bank addresses, numbers of sensors in that bank, |
| number of bytes data per sensor and contents/meaning of those bytes. |
| |
| Although both this document and the kernel driver have kept the sensor |
| terminoligy for the addressing within a bank this is not 100% correct, in |
| bank 0x24 for example the addressing within the bank selects a PWM output not |
| a sensor. |
| |
| Notice that some banks have both a read and a write address this is how the |
| uGuru determines if a read from or a write to the bank is taking place, thus |
| when reading you should always use the read address and when writing the |
| write address. The write address is always one (1) more then the read address. |
| |
| |
| uGuru ready |
| ----------- |
| |
| Before you can read from or write to the uGuru you must first put the uGuru |
| in "ready" mode. |
| |
| To put the uGuru in ready mode first write 0x00 to DATA and then wait for DATA |
| to hold 0x09, DATA should read 0x09 within 250 read cycles. |
| |
| Next CMD _must_ be read and should hold 0xAC, usually CMD will hold 0xAC the |
| first read but sometimes it takes a while before CMD holds 0xAC and thus it |
| has to be read a number of times (max 50). |
| |
| After reading CMD, DATA should hold 0x08 which means that the uGuru is ready |
| for input. As above DATA will usually hold 0x08 the first read but not always. |
| This step can be skipped, but it is undetermined what happens if the uGuru has |
| not yet reported 0x08 at DATA and you proceed with writing a bank address. |
| |
| |
| Sending bank and sensor addresses to the uGuru |
| ---------------------------------------------- |
| |
| First the uGuru must be in "ready" mode as described above, DATA should hold |
| 0x08 indicating that the uGuru wants input, in this case the bank address. |
| |
| Next write the bank address to DATA. After the bank address has been written |
| wait for to DATA to hold 0x08 again indicating that it wants / is ready for |
| more input (max 250 reads). |
| |
| Once DATA holds 0x08 again write the sensor address to CMD. |
| |
| |
| Reading |
| ------- |
| |
| First send the bank and sensor addresses as described above. |
| Then for each byte of data you want to read wait for DATA to hold 0x01 |
| which indicates that the uGuru is ready to be read (max 250 reads) and once |
| DATA holds 0x01 read the byte from CMD. |
| |
| Once all bytes have been read data will hold 0x09, but there is no reason to |
| test for this. Notice that the number of bytes is bank address dependent see |
| above and below. |
| |
| After completing a successfull read it is advised to put the uGuru back in |
| ready mode, so that it is ready for the next read / write cycle. This way |
| if your program / driver is unloaded and later loaded again the detection |
| algorithm described above will still work. |
| |
| |
| |
| Writing |
| ------- |
| |
| First send the bank and sensor addresses as described above. |
| Then for each byte of data you want to write wait for DATA to hold 0x00 |
| which indicates that the uGuru is ready to be written (max 250 reads) and |
| once DATA holds 0x00 write the byte to CMD. |
| |
| Once all bytes have been written wait for DATA to hold 0x01 (max 250 reads) |
| don't ask why this is the way it is. |
| |
| Once DATA holds 0x01 read CMD it should hold 0xAC now. |
| |
| After completing a successfull write it is advised to put the uGuru back in |
| ready mode, so that it is ready for the next read / write cycle. This way |
| if your program / driver is unloaded and later loaded again the detection |
| algorithm described above will still work. |
| |
| |
| Gotchas |
| ------- |
| |
| After wider testing of the Linux kernel driver some variants of the uGuru have |
| turned up which do not hold 0x08 at DATA within 250 reads after writing the |
| bank address. With these versions this happens quite frequent, using larger |
| timeouts doesn't help, they just go offline for a second or 2, doing some |
| internal callibration or whatever. Your code should be prepared to handle |
| this and in case of no response in this specific case just goto sleep for a |
| while and then retry. |
| |
| |
| Address Map |
| =========== |
| |
| Bank 0x20 Alarms (R) |
| -------------------- |
| This bank contains 0 sensors, iow the sensor address is ignored (but must be |
| written) just use 0. Bank 0x20 contains 3 bytes: |
| |
| Byte 0: |
| This byte holds the alarm flags for sensor 0-7 of Sensor Bank1, with bit 0 |
| corresponding to sensor 0, 1 to 1, etc. |
| |
| Byte 1: |
| This byte holds the alarm flags for sensor 8-15 of Sensor Bank1, with bit 0 |
| corresponding to sensor 8, 1 to 9, etc. |
| |
| Byte 2: |
| This byte holds the alarm flags for sensor 0-5 of Sensor Bank2, with bit 0 |
| corresponding to sensor 0, 1 to 1, etc. |
| |
| |
| Bank 0x21 Sensor Bank1 Values / Readings (R) |
| -------------------------------------------- |
| This bank contains 16 sensors, for each sensor it contains 1 byte. |
| So far the following sensors are known to be available on all motherboards: |
| Sensor 0 CPU temp |
| Sensor 1 SYS temp |
| Sensor 3 CPU core volt |
| Sensor 4 DDR volt |
| Sensor 10 DDR Vtt volt |
| Sensor 15 PWM temp |
| |
| Byte 0: |
| This byte holds the reading from the sensor. Sensors in Bank1 can be both |
| volt and temp sensors, this is motherboard specific. The uGuru however does |
| seem to know (be programmed with) what kindoff sensor is attached see Sensor |
| Bank1 Settings description. |
| |
| Volt sensors use a linear scale, a reading 0 corresponds with 0 volt and a |
| reading of 255 with 3494 mV. The sensors for higher voltages however are |
| connected through a division circuit. The currently known division circuits |
| in use result in ranges of: 0-4361mV, 0-6248mV or 0-14510mV. 3.3 volt sources |
| use the 0-4361mV range, 5 volt the 0-6248mV and 12 volt the 0-14510mV . |
| |
| Temp sensors also use a linear scale, a reading of 0 corresponds with 0 degree |
| Celsius and a reading of 255 with a reading of 255 degrees Celsius. |
| |
| |
| Bank 0x22 Sensor Bank1 Settings (R) |
| Bank 0x23 Sensor Bank1 Settings (W) |
| ----------------------------------- |
| |
| This bank contains 16 sensors, for each sensor it contains 3 bytes. Each |
| set of 3 bytes contains the settings for the sensor with the same sensor |
| address in Bank 0x21 . |
| |
| Byte 0: |
| Alarm behaviour for the selected sensor. A 1 enables the described behaviour. |
| Bit 0: Give an alarm if measured temp is over the warning threshold (RW) * |
| Bit 1: Give an alarm if measured volt is over the max threshold (RW) ** |
| Bit 2: Give an alarm if measured volt is under the min threshold (RW) ** |
| Bit 3: Beep if alarm (RW) |
| Bit 4: 1 if alarm cause measured temp is over the warning threshold (R) |
| Bit 5: 1 if alarm cause measured volt is over the max threshold (R) |
| Bit 6: 1 if alarm cause measured volt is under the min threshold (R) |
| Bit 7: Volt sensor: Shutdown if alarm persist for more then 4 seconds (RW) |
| Temp sensor: Shutdown if temp is over the shutdown threshold (RW) |
| |
| * This bit is only honored/used by the uGuru if a temp sensor is connected |
| ** This bit is only honored/used by the uGuru if a volt sensor is connected |
| Note with some trickery this can be used to find out what kinda sensor is |
| detected see the Linux kernel driver for an example with many comments on |
| how todo this. |
| |
| Byte 1: |
| Temp sensor: warning threshold (scale as bank 0x21) |
| Volt sensor: min threshold (scale as bank 0x21) |
| |
| Byte 2: |
| Temp sensor: shutdown threshold (scale as bank 0x21) |
| Volt sensor: max threshold (scale as bank 0x21) |
| |
| |
| Bank 0x24 PWM outputs for FAN's (R) |
| Bank 0x25 PWM outputs for FAN's (W) |
| ----------------------------------- |
| |
| This bank contains 3 "sensors", for each sensor it contains 5 bytes. |
| Sensor 0 usually controls the CPU fan |
| Sensor 1 usually controls the NB (or chipset for single chip) fan |
| Sensor 2 usually controls the System fan |
| |
| Byte 0: |
| Flag 0x80 to enable control, Fan runs at 100% when disabled. |
| low nibble (temp)sensor address at bank 0x21 used for control. |
| |
| Byte 1: |
| 0-255 = 0-12v (linear), specify voltage at which fan will rotate when under |
| low threshold temp (specified in byte 3) |
| |
| Byte 2: |
| 0-255 = 0-12v (linear), specify voltage at which fan will rotate when above |
| high threshold temp (specified in byte 4) |
| |
| Byte 3: |
| Low threshold temp (scale as bank 0x21) |
| |
| byte 4: |
| High threshold temp (scale as bank 0x21) |
| |
| |
| Bank 0x26 Sensors Bank2 Values / Readings (R) |
| --------------------------------------------- |
| |
| This bank contains 6 sensors (AFAIK), for each sensor it contains 1 byte. |
| So far the following sensors are known to be available on all motherboards: |
| Sensor 0: CPU fan speed |
| Sensor 1: NB (or chipset for single chip) fan speed |
| Sensor 2: SYS fan speed |
| |
| Byte 0: |
| This byte holds the reading from the sensor. 0-255 = 0-15300 (linear) |
| |
| |
| Bank 0x27 Sensors Bank2 Settings (R) |
| Bank 0x28 Sensors Bank2 Settings (W) |
| ------------------------------------ |
| |
| This bank contains 6 sensors (AFAIK), for each sensor it contains 2 bytes. |
| |
| Byte 0: |
| Alarm behaviour for the selected sensor. A 1 enables the described behaviour. |
| Bit 0: Give an alarm if measured rpm is under the min threshold (RW) |
| Bit 3: Beep if alarm (RW) |
| Bit 7: Shutdown if alarm persist for more then 4 seconds (RW) |
| |
| Byte 1: |
| min threshold (scale as bank 0x26) |
| |
| |
| Warning for the adventerous |
| =========================== |
| |
| A word of caution to those who want to experiment and see if they can figure |
| the voltage / clock programming out, I tried reading and only reading banks |
| 0-0x30 with the reading code used for the sensor banks (0x20-0x28) and this |
| resulted in a _permanent_ reprogramming of the voltages, luckily I had the |
| sensors part configured so that it would shutdown my system on any out of spec |
| voltages which proprably safed my computer (after a reboot I managed to |
| immediatly enter the bios and reload the defaults). This probably means that |
| the read/write cycle for the non sensor part is different from the sensor part. |