| * Linux/PARISC Project (http://www.parisc-linux.org/) |
| * |
| * HP-UX System Call Wrapper routines and System Call Return Path |
| * |
| * Copyright (C) 2000 Hewlett-Packard (John Marvin) |
| * |
| * This program is free software; you can redistribute it and/or modify |
| * it under the terms of the GNU General Public License as published by |
| * the Free Software Foundation; either version 2, or (at your option) |
| * any later version. |
| * |
| * This program is distributed in the hope that it will be useful, |
| * but WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
| * GNU General Public License for more details. |
| * |
| * You should have received a copy of the GNU General Public License |
| * along with this program; if not, write to the Free Software |
| * Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA. |
| */ |
| |
| #ifdef __LP64__ |
| #warning PA64 support needs more work...did first cut |
| #endif |
| |
| #include <asm/asm-offsets.h> |
| #include <asm/assembly.h> |
| #include <asm/signal.h> |
| |
| #ifdef __LP64__ |
| .level 2.0w |
| #else |
| .level 1.1 |
| #endif |
| .text |
| |
| /* These should probably go in a header file somewhere. |
| * They are duplicated in kernel/wrappers.S |
| * Possibly we should consider consolidating these |
| * register save/restore macros. |
| */ |
| .macro reg_save regs |
| #ifdef __LP64__ |
| #warning NEEDS WORK for 64-bit |
| #endif |
| STREG %r3, PT_GR3(\regs) |
| STREG %r4, PT_GR4(\regs) |
| STREG %r5, PT_GR5(\regs) |
| STREG %r6, PT_GR6(\regs) |
| STREG %r7, PT_GR7(\regs) |
| STREG %r8, PT_GR8(\regs) |
| STREG %r9, PT_GR9(\regs) |
| STREG %r10,PT_GR10(\regs) |
| STREG %r11,PT_GR11(\regs) |
| STREG %r12,PT_GR12(\regs) |
| STREG %r13,PT_GR13(\regs) |
| STREG %r14,PT_GR14(\regs) |
| STREG %r15,PT_GR15(\regs) |
| STREG %r16,PT_GR16(\regs) |
| STREG %r17,PT_GR17(\regs) |
| STREG %r18,PT_GR18(\regs) |
| .endm |
| |
| .macro reg_restore regs |
| LDREG PT_GR3(\regs), %r3 |
| LDREG PT_GR4(\regs), %r4 |
| LDREG PT_GR5(\regs), %r5 |
| LDREG PT_GR6(\regs), %r6 |
| LDREG PT_GR7(\regs), %r7 |
| LDREG PT_GR8(\regs), %r8 |
| LDREG PT_GR9(\regs), %r9 |
| LDREG PT_GR10(\regs),%r10 |
| LDREG PT_GR11(\regs),%r11 |
| LDREG PT_GR12(\regs),%r12 |
| LDREG PT_GR13(\regs),%r13 |
| LDREG PT_GR14(\regs),%r14 |
| LDREG PT_GR15(\regs),%r15 |
| LDREG PT_GR16(\regs),%r16 |
| LDREG PT_GR17(\regs),%r17 |
| LDREG PT_GR18(\regs),%r18 |
| .endm |
| |
| |
| .export hpux_fork_wrapper |
| .export hpux_child_return |
| .import sys_fork |
| |
| hpux_fork_wrapper: |
| ldo TASK_REGS-TASK_SZ_ALGN-64(%r30),%r1 ;! get pt regs |
| ;! pointer in task |
| reg_save %r1 |
| |
| STREG %r2,-20(%r30) |
| ldo 64(%r30),%r30 |
| STREG %r2,PT_GR19(%r1) ;! save for child |
| STREG %r30,PT_GR21(%r1) ;! save for child |
| |
| LDREG PT_GR30(%r1),%r25 |
| mtctl %r25,%cr29 |
| copy %r1,%r24 |
| bl sys_clone,%r2 |
| ldi SIGCHLD,%r26 |
| |
| LDREG -84(%r30),%r2 |
| fork_return: |
| ldo -64(%r30),%r30 |
| ldo TASK_REGS-TASK_SZ_ALGN-64(%r30),%r1 ;! get pt regs |
| |
| reg_restore %r1 |
| |
| /* |
| * HP-UX wants pid (child gets parent pid, parent gets child pid) |
| * in r28 and a flag in r29 (r29 == 1 for child, 0 for parent). |
| * Linux fork returns 0 for child, pid for parent. Since HP-UX |
| * libc stub throws away parent pid and returns 0 for child, |
| * we'll just return 0 for parent pid now. Only applications |
| * that jump directly to the gateway page (not supported) will |
| * know the difference. We can fix this later if necessary. |
| */ |
| |
| ldo -1024(%r0),%r1 |
| comb,>>=,n %r28,%r1,fork_exit /* just let the syscall exit handle it */ |
| or,= %r28,%r0,%r0 |
| or,tr %r0,%r0,%r29 /* r28 <> 0, we are parent, set r29 to 0 */ |
| ldo 1(%r0),%r29 /* r28 == 0, we are child, set r29 to 1 */ |
| |
| fork_exit: |
| bv %r0(%r2) |
| nop |
| |
| /* Set the return value for the child */ |
| |
| hpux_child_return: |
| #if defined(CONFIG_SMP) || defined(CONFIG_PREEMPT) |
| bl schedule_tail, %r2 |
| nop |
| #endif |
| |
| LDREG TASK_PT_GR19-TASK_SZ_ALGN-128(%r30),%r2 |
| b fork_return |
| copy %r0,%r28 |
| |
| .export hpux_execve_wrapper |
| .export hpux_execv_wrapper |
| .import hpux_execve |
| |
| hpux_execv_wrapper: |
| copy %r0,%r24 /* NULL environment */ |
| |
| hpux_execve_wrapper: |
| |
| ldo TASK_REGS-TASK_SZ_ALGN-64(%r30),%r1 ;! get pt regs |
| |
| /* |
| * Do we need to save/restore r3-r18 here? |
| * I don't think so. why would new thread need old |
| * threads registers? |
| */ |
| |
| /* Store arg0, arg1 and arg2 so that hpux_execve will find them */ |
| |
| STREG %r26,PT_GR26(%r1) |
| STREG %r25,PT_GR25(%r1) |
| STREG %r24,PT_GR24(%r1) |
| |
| STREG %r2,-20(%r30) |
| ldo 64(%r30),%r30 |
| bl hpux_execve,%r2 |
| copy %r1,%arg0 |
| |
| ldo -64(%r30),%r30 |
| LDREG -20(%r30),%r2 |
| |
| /* If exec succeeded we need to load the args */ |
| |
| ldo -1024(%r0),%r1 |
| comb,>>= %r28,%r1,exec_error |
| copy %r2,%r19 |
| ldo -TASK_SZ_ALGN-64(%r30),%r1 ;! get task ptr |
| LDREG TASK_PT_GR26(%r1),%r26 |
| LDREG TASK_PT_GR25(%r1),%r25 |
| LDREG TASK_PT_GR24(%r1),%r24 |
| LDREG TASK_PT_GR23(%r1),%r23 |
| copy %r0,%r2 /* Flag to syscall_exit not to clear args */ |
| |
| exec_error: |
| bv %r0(%r19) |
| nop |
| |
| .export hpux_pipe_wrapper |
| .import hpux_pipe |
| |
| /* HP-UX expects pipefd's returned in r28 & r29 */ |
| |
| hpux_pipe_wrapper: |
| STREG %r2,-20(%r30) |
| ldo 64(%r30),%r30 |
| bl hpux_pipe,%r2 |
| ldo -56(%r30),%r26 /* pass local array to hpux_pipe */ |
| |
| |
| ldo -1024(%r0),%r1 |
| comb,>>= %r28,%r1,pipe_exit /* let syscall exit handle it */ |
| LDREG -84(%r30),%r2 |
| |
| /* if success, load fd's from stack array */ |
| |
| LDREG -56(%r30),%r28 |
| LDREG -52(%r30),%r29 |
| |
| pipe_exit: |
| bv %r0(%r2) |
| ldo -64(%r30),%r30 |
| |
| .export hpux_syscall_exit |
| .import syscall_exit |
| |
| hpux_syscall_exit: |
| |
| /* |
| * |
| * HP-UX call return conventions: |
| * |
| * if error: |
| * r22 = 1 |
| * r28 = errno value |
| * r29 = secondary return value |
| * else |
| * r22 = 0 |
| * r28 = return value |
| * r29 = secondary return value |
| * |
| * For now, we'll just check to see if r28 is < (unsigned long)-1024 |
| * (to handle addresses > 2 Gb) and if so set r22 to zero. If not, |
| * we'll complement r28 and set r22 to 1. Wrappers will be |
| * needed for syscalls that care about the secondary return value. |
| * The wrapper may also need a way of avoiding the following code, |
| * but we'll deal with that when it becomes necessary. |
| */ |
| |
| ldo -1024(%r0),%r1 |
| comb,<< %r28,%r1,no_error |
| copy %r0,%r22 |
| subi 0,%r28,%r28 |
| ldo 1(%r0),%r22 |
| |
| no_error: |
| b syscall_exit |
| nop |
| |
| .export hpux_unimplemented_wrapper |
| .import hpux_unimplemented |
| |
| hpux_unimplemented_wrapper: |
| b hpux_unimplemented |
| STREG %r22,-64(%r30) /* overwrite arg8 with syscall number */ |