blob: feb830130714ad3710afb529105ab70e0e228c90 [file] [log] [blame]
Device Tree Clock bindings for cpu clock of Marvell EBU platforms
Required properties:
- compatible : shall be one of the following:
"marvell,armada-xp-cpu-clock" - cpu clocks for Armada XP
- reg : Address and length of the clock complex register set
- #clock-cells : should be set to 1.
- clocks : shall be the input parent clock phandle for the clock.
cpuclk: clock-complex@d0018700 {
#clock-cells = <1>;
compatible = "marvell,armada-xp-cpu-clock";
reg = <0xd0018700 0xA0>;
clocks = <&coreclk 1>;
}
cpu@0 {
compatible = "marvell,sheeva-v7";
reg = <0>;
clocks = <&cpuclk 0>;
};