IB/core: Set static rate in ib_init_ah_from_path()

The static rate from the path record should be put into the address
vector -- a long time ago the rate in the address attributes needed to
be a relative rate, which required more munging, but now that the
conversion from absolute to relative is done in the low-level driver,
it's easy for ib_init_ah_from_path() to put the absolute rate in.

Cc: Jason Gunthorpe <jgunthorpe@obsidianresearch.com>
Cc: Sean Hefty <sean.hefty@intel.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
diff --git a/drivers/infiniband/core/sa_query.c b/drivers/infiniband/core/sa_query.c
index d7d4a53..68db633 100644
--- a/drivers/infiniband/core/sa_query.c
+++ b/drivers/infiniband/core/sa_query.c
@@ -471,6 +471,7 @@
 	ah_attr->sl = rec->sl;
 	ah_attr->src_path_bits = be16_to_cpu(rec->slid) & 0x7f;
 	ah_attr->port_num = port_num;
+	ah_attr->static_rate = rec->rate;
 
 	if (rec->hop_limit > 1) {
 		ah_attr->ah_flags = IB_AH_GRH;