Bluetooth: Use proper timer for hci command timout

Use proper timer instead of hci command flow control to timeout
failed hci commands. Otherwise stack ends up sending commands
when flow control is used to block new commands.

2010-09-01 18:29:41.592132 < HCI Command: Remote Name Request (0x01|0x0019) plen 10
    bdaddr 00:16:CF:E1:C7:D7 mode 2 clkoffset 0x0000
2010-09-01 18:29:41.592681 > HCI Event: Command Status (0x0f) plen 4
    Remote Name Request (0x01|0x0019) status 0x00 ncmd 0
2010-09-01 18:29:51.022033 < HCI Command: Remote Name Request Cancel (0x01|0x001a) plen 6
    bdaddr 00:16:CF:E1:C7:D7

Signed-off-by: Ville Tervo <ville.tervo@nokia.com>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
diff --git a/include/net/bluetooth/hci_core.h b/include/net/bluetooth/hci_core.h
index d30b93c..ecd2acf 100644
--- a/include/net/bluetooth/hci_core.h
+++ b/include/net/bluetooth/hci_core.h
@@ -132,7 +132,6 @@
 	unsigned int	sco_pkts;
 	unsigned int	le_pkts;
 
-	unsigned long	cmd_last_tx;
 	unsigned long	acl_last_tx;
 	unsigned long	sco_last_tx;
 	unsigned long	le_last_tx;
@@ -143,6 +142,7 @@
 	struct work_struct	power_off;
 	struct timer_list	off_timer;
 
+	struct timer_list	cmd_timer;
 	struct tasklet_struct	cmd_task;
 	struct tasklet_struct	rx_task;
 	struct tasklet_struct	tx_task;